{"id":37312,"date":"2022-08-10T14:56:05","date_gmt":"2022-08-10T13:56:05","guid":{"rendered":"https:\/\/www.atim.com\/ht-faq\/new-faq-question-39\/"},"modified":"2022-08-10T15:13:04","modified_gmt":"2022-08-10T14:13:04","slug":"new-faq-question-39","status":"publish","type":"ht_faq","link":"https:\/\/www.atim.com\/de\/ht-faq\/new-faq-question-39\/","title":{"rendered":"What if the connection is not established and the 2 RJ45 LEDs remain lit-fixed and the ARM-SE is powered on?"},"content":{"rendered":"<p>This indicates that the equipment connected to the ARM-SE is not at the right speed, in fact the ARM-SE supports a maximum speed of 10Mbps and this happens if it receives frames at 100Mbps for example.<\/p>\n<p>In this case, you just have to set the speed of your equipment to 10Mbps or automatic. On a PC, you need to set the network card speed to AUTO.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This indicates that the equipment connected to the ARM-SE is not at the right speed, in fact the ARM-SE supports<\/p>\n","protected":false},"author":19,"template":"","ht-faq-group":[1493],"class_list":["post-37312","ht_faq","type-ht_faq","status-publish","hentry"],"acf":[],"display_content":"<p>This indicates that the equipment connected to the ARM-SE is not at the right speed, in fact the ARM-SE supports a maximum speed of 10Mbps and this happens if it receives frames at 100Mbps for example.<\/p><p>In this case, you just have to set the speed of your equipment to 10Mbps or automatic. On a PC, you need to set the network card speed to AUTO.<\/p>","display_excerpt":"This indicates that the equipment connected to the ARM-SE is not at the right speed, in fact the ARM-SE supports","_ht_faq_order":"2","_ht_faq_enabled":"1","yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>What if the connection is not established and the 2 RJ45 LEDs remain lit-fixed and the ARM-SE is powered on? - ATIM<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.atim.com\/ht-faq\/new-faq-question-39\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What if the connection is not established and the 2 RJ45 LEDs remain lit-fixed and the ARM-SE is powered on? - ATIM\" \/>\n<meta property=\"og:description\" content=\"This indicates that the equipment connected to the ARM-SE is not at the right speed, in fact the ARM-SE supports\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.atim.com\/ht-faq\/new-faq-question-39\/\" \/>\n<meta property=\"og:site_name\" content=\"ATIM\" \/>\n<meta property=\"article:modified_time\" content=\"2022-08-10T14:13:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.atim.com\/wp-content\/uploads\/2015\/07\/atim_flat-e1440686224565.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@ATIMRadio\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.atim.com\\\/ht-faq\\\/new-faq-question-39\\\/\",\"url\":\"https:\\\/\\\/www.atim.com\\\/ht-faq\\\/new-faq-question-39\\\/\",\"name\":\"What if the connection is not established and the 2 RJ45 LEDs remain lit-fixed and the ARM-SE is powered on? - ATIM\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.atim.com\\\/en\\\/#website\"},\"datePublished\":\"2022-08-10T13:56:05+00:00\",\"dateModified\":\"2022-08-10T14:13:04+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.atim.com\\\/ht-faq\\\/new-faq-question-39\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.atim.com\\\/ht-faq\\\/new-faq-question-39\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.atim.com\\\/ht-faq\\\/new-faq-question-39\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/www.atim.com\\\/de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"FAQs\",\"item\":\"https:\\\/\\\/www.atim.com\\\/ht-faq\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"What if the connection is not established and the 2 RJ45 LEDs remain lit-fixed and the ARM-SE is powered on?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.atim.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.atim.com\\\/en\\\/\",\"name\":\"ATIM\",\"description\":\"ATIM connects everything\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.atim.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.atim.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.atim.com\\\/en\\\/#organization\",\"name\":\"ATIM Radiocomunication\",\"url\":\"https:\\\/\\\/www.atim.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.atim.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.atim.com\\\/wp-content\\\/uploads\\\/2021\\\/06\\\/logo-atim-130.png\",\"contentUrl\":\"https:\\\/\\\/www.atim.com\\\/wp-content\\\/uploads\\\/2021\\\/06\\\/logo-atim-130.png\",\"width\":131,\"height\":84,\"caption\":\"ATIM Radiocomunication\"},\"image\":{\"@id\":\"https:\\\/\\\/www.atim.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/ATIMRadio\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/atim-radiocommunications\\\/?viewAsMember=true\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCnpb2_Mt4vG2iBkyQX58Zxg\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"What if the connection is not established and the 2 RJ45 LEDs remain lit-fixed and the ARM-SE is powered on? - ATIM","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.atim.com\/ht-faq\/new-faq-question-39\/","og_locale":"de_DE","og_type":"article","og_title":"What if the connection is not established and the 2 RJ45 LEDs remain lit-fixed and the ARM-SE is powered on? - ATIM","og_description":"This indicates that the equipment connected to the ARM-SE is not at the right speed, in fact the ARM-SE supports","og_url":"https:\/\/www.atim.com\/ht-faq\/new-faq-question-39\/","og_site_name":"ATIM","article_modified_time":"2022-08-10T14:13:04+00:00","og_image":[{"url":"https:\/\/www.atim.com\/wp-content\/uploads\/2015\/07\/atim_flat-e1440686224565.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_site":"@ATIMRadio","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.atim.com\/ht-faq\/new-faq-question-39\/","url":"https:\/\/www.atim.com\/ht-faq\/new-faq-question-39\/","name":"What if the connection is not established and the 2 RJ45 LEDs remain lit-fixed and the ARM-SE is powered on? - ATIM","isPartOf":{"@id":"https:\/\/www.atim.com\/en\/#website"},"datePublished":"2022-08-10T13:56:05+00:00","dateModified":"2022-08-10T14:13:04+00:00","breadcrumb":{"@id":"https:\/\/www.atim.com\/ht-faq\/new-faq-question-39\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.atim.com\/ht-faq\/new-faq-question-39\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.atim.com\/ht-faq\/new-faq-question-39\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.atim.com\/de\/"},{"@type":"ListItem","position":2,"name":"FAQs","item":"https:\/\/www.atim.com\/ht-faq\/"},{"@type":"ListItem","position":3,"name":"What if the connection is not established and the 2 RJ45 LEDs remain lit-fixed and the ARM-SE is powered on?"}]},{"@type":"WebSite","@id":"https:\/\/www.atim.com\/en\/#website","url":"https:\/\/www.atim.com\/en\/","name":"ATIM","description":"ATIM connects everything","publisher":{"@id":"https:\/\/www.atim.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.atim.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.atim.com\/en\/#organization","name":"ATIM Radiocomunication","url":"https:\/\/www.atim.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.atim.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.atim.com\/wp-content\/uploads\/2021\/06\/logo-atim-130.png","contentUrl":"https:\/\/www.atim.com\/wp-content\/uploads\/2021\/06\/logo-atim-130.png","width":131,"height":84,"caption":"ATIM Radiocomunication"},"image":{"@id":"https:\/\/www.atim.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/ATIMRadio","https:\/\/www.linkedin.com\/company\/atim-radiocommunications\/?viewAsMember=true","https:\/\/www.youtube.com\/channel\/UCnpb2_Mt4vG2iBkyQX58Zxg"]}]}},"_links":{"self":[{"href":"https:\/\/www.atim.com\/de\/wp-json\/wp\/v2\/ht-faq\/37312","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.atim.com\/de\/wp-json\/wp\/v2\/ht-faq"}],"about":[{"href":"https:\/\/www.atim.com\/de\/wp-json\/wp\/v2\/types\/ht_faq"}],"author":[{"embeddable":true,"href":"https:\/\/www.atim.com\/de\/wp-json\/wp\/v2\/users\/19"}],"version-history":[{"count":0,"href":"https:\/\/www.atim.com\/de\/wp-json\/wp\/v2\/ht-faq\/37312\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.atim.com\/de\/wp-json\/wp\/v2\/media?parent=37312"}],"wp:term":[{"taxonomy":"ht_faq_group","embeddable":true,"href":"https:\/\/www.atim.com\/de\/wp-json\/wp\/v2\/ht-faq-group?post=37312"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}