{"id":46456,"date":"2026-01-21T16:25:46","date_gmt":"2026-01-21T15:25:46","guid":{"rendered":"https:\/\/www.atim.com\/?post_type=product&#038;p=46456"},"modified":"2026-03-04T16:54:32","modified_gmt":"2026-03-04T15:54:32","slug":"enerclip-ct-measurement-unit-modbus-and-relay-output","status":"publish","type":"product","link":"https:\/\/www.atim.com\/en\/produits\/enerclip-ct-measurement-unit-modbus-and-relay-output\/","title":{"rendered":"ACW-MSC-N2<br>Measurement unit<br><b>for Enerclip CTs <\/b><br>Modbus and relay output"},"content":{"rendered":"<table>\n<tbody>\n<tr>\n<td class=\"titre\" bgcolor=\"#E9E9E9\"><strong>MEASUREMENT RANGE<\/strong><\/td>\n<td>Measurement of 1 three-phase circuit or 3 single-phase circuits using 3 inputs for Enerclip current transformers, with voltage measurement performed directly or via associated voltage transformers.<\/td>\n<\/tr>\n<tr>\n<td class=\"titre\" bgcolor=\"#E9E9E9\"><strong>ACCURACY<\/strong><\/td>\n<td>Class 0.5S for active energy (compliant with industrial electrical measurement standards).<\/td>\n<\/tr>\n<tr>\n<td class=\"titre\" bgcolor=\"#E9E9E9\"><strong>POWER SUPPLY*<\/strong><\/td>\n<td>Self-powered via the measured circuit (no autonomous battery).<\/td>\n<\/tr>\n<tr>\n<td class=\"titre\" bgcolor=\"#E9E9E9\"><strong>BATTERY<\/strong><\/td>\n<td>No internal battery \u2014 powered directly from the measured electrical circuit.<\/td>\n<\/tr>\n<tr>\n<td class=\"titre\" bgcolor=\"#E9E9E9\"><strong>ENCLOSURE<\/strong><\/td>\n<td>Compact 1-module-wide enclosure, clip-mounted on standard DIN rail in electrical cabinets.<\/td>\n<\/tr>\n<tr>\n<td class=\"titre\" bgcolor=\"#E9E9E9\"><strong>OPERATING MODES<\/strong><\/td>\n<td>Instantaneous and aggregated measurements of electrical parameters (energy, demand, extreme values, harmonics up to the 63rd order), programmable relay, digital inputs for circuit status or pulse counting.<\/td>\n<\/tr>\n<tr>\n<td class=\"titre\" bgcolor=\"#E9E9E9\"><strong>CONFIGURATION<\/strong><\/td>\n<td>Modbus RTU communication via RS485, configurable parameters, relay threshold programming, and monitoring\/programming via software or optional display.<\/td>\n<\/tr>\n<tr>\n<td class=\"titre\" bgcolor=\"#E9E9E9\"><strong>PLUG &amp; PLAY<\/strong><\/td>\n<td>Installation in under 10 minutes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>* Product autonomy depends on several external factors (ambient temperature and humidity, transmission frequency, network quality, etc.)<\/p>\n<div id=\"footable_parent_46471\"\n         class=\" footable_parent ninja_table_wrapper loading_ninja_table wp_table_data_press_parent semantic_ui \">\n                    <h3 class=\"table_title footable_title\">MSC-N2<\/h3>\n                                <div\n                class=\"table_description footable_description\"><\/div>\n                    <table data-ninja_table_instance=\"ninja_table_instance_0\" data-footable_id=\"46471\" data-filter-delay=\"1000\" aria-label=\"MSC-N2\"            id=\"footable_46471\"\n           data-unique_identifier=\"ninja_table_unique_id_2081385107_46471\"\n           class=\" foo-table ninja_footable foo_table_46471 ninja_table_unique_id_2081385107_46471 ui table  ninja_search_left nt_type_ajax_table single line fixed selectable celled striped compact vertical_centered  footable-paging-left ninja_table_search_disabled ninja_table_pro\">\n                <colgroup>\n                            <col class=\"ninja_column_0 \">\n                            <col class=\"ninja_column_1 \">\n                            <col class=\"ninja_column_2 \">\n                            <col class=\"ninja_column_3 \">\n                            <col class=\"ninja_column_4 \">\n                    <\/colgroup>\n            <\/table>\n    \n    \n    \n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<header class=\"b-heading\">\n<h3 class=\"b-exc\"><strong>Power Meter for Enerclip CTs \u2013 Modbus and Relay Output<\/strong><\/h3>\n<\/header>\n<p data-start=\"143\" data-end=\"458\">The Enerclip MSC-N2 measurement module enables <strong>complete measurement of electrical parameters for one three-phase circuit or three single-phase circuits<\/strong>, thanks to its three inputs for Enerclip current transformers and its ability to measure voltage, current, power, energy, harmonics and associated electrical parameters.<\/p>\n<p data-start=\"460\" data-end=\"669\">Thanks to its compact DIN-rail format (1 module wide) and power supply drawn directly from the measured circuit, the MSC-N2 integrates easily into electrical cabinets without the need for an external battery.<\/p>\n<p data-start=\"671\" data-end=\"867\">A programmable relay and digital inputs are integrated: when a configured threshold is exceeded or an input state is detected, actions or alerts can be triggered immediately.<\/p>\n<p data-start=\"869\" data-end=\"1078\">Measurements are transmitted via industrial Modbus RTU communication over RS485, and configuration can be performed remotely or locally using the supervision software or via the optional display.<\/p>\n<p data-start=\"1080\" data-end=\"1330\">Compatible with electrical monitoring and analysis software, data visualization, remote module configuration and relay setup based on predefined thresholds can be performed in just a few clicks.<\/p>\n<p data-start=\"1080\" data-end=\"1330\"><strong>See also<\/strong><a href=\"https:\/\/www.atim.com\/en\/produits\/modular-multi-input-measurement-unit\/\" target=\"_blank\" rel=\"noopener\"><br \/>\n<strong>Modular Multi-Input Power Meter<\/strong><br \/>\n<\/a><\/p>\n","protected":false},"featured_media":46463,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"inline_featured_image":false},"product_brand":[],"product_cat":[1176],"product_tag":[759,641],"class_list":{"0":"post-46456","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-telereleve-metering-en","7":"product_tag-lorawan_en","8":"product_tag-sigfox_en","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Enerclip CT measurement unit \u2013 Modbus and relay output<\/title>\n<meta name=\"description\" content=\"The Enerclip MSC-N2 measurement module enables comprehensive measurement of electrical quantities in a three-phase circuit or three single-phase circuits.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.atim.com\/en\/produits\/enerclip-ct-measurement-unit-modbus-and-relay-output\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Enerclip CT measurement unit \u2013 Modbus and relay output\" \/>\n<meta property=\"og:description\" content=\"The Enerclip MSC-N2 measurement module enables comprehensive measurement of electrical quantities in a three-phase circuit or three single-phase circuits.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.atim.com\/en\/produits\/enerclip-ct-measurement-unit-modbus-and-relay-output\/\" \/>\n<meta property=\"og:site_name\" content=\"ATIM\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-04T15:54:32+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.atim.com\/wp-content\/uploads\/2026\/01\/MSC-N2-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"440\" \/>\n\t<meta property=\"og:image:height\" content=\"440\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@ATIMRadio\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.atim.com\\\/en\\\/produits\\\/enerclip-ct-measurement-unit-modbus-and-relay-output\\\/\",\"url\":\"https:\\\/\\\/www.atim.com\\\/en\\\/produits\\\/enerclip-ct-measurement-unit-modbus-and-relay-output\\\/\",\"name\":\"Enerclip CT measurement unit \u2013 Modbus and relay output\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.atim.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.atim.com\\\/en\\\/produits\\\/enerclip-ct-measurement-unit-modbus-and-relay-output\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.atim.com\\\/en\\\/produits\\\/enerclip-ct-measurement-unit-modbus-and-relay-output\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.atim.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/MSC-N2-1.png\",\"datePublished\":\"2026-01-21T15:25:46+00:00\",\"dateModified\":\"2026-03-04T15:54:32+00:00\",\"description\":\"The Enerclip MSC-N2 measurement module enables comprehensive measurement of electrical quantities in a three-phase circuit or three single-phase circuits.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.atim.com\\\/en\\\/produits\\\/enerclip-ct-measurement-unit-modbus-and-relay-output\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.atim.com\\\/en\\\/produits\\\/enerclip-ct-measurement-unit-modbus-and-relay-output\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.atim.com\\\/en\\\/produits\\\/enerclip-ct-measurement-unit-modbus-and-relay-output\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.atim.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/MSC-N2-1.png\",\"contentUrl\":\"https:\\\/\\\/www.atim.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/MSC-N2-1.png\",\"width\":440,\"height\":440},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.atim.com\\\/en\\\/produits\\\/enerclip-ct-measurement-unit-modbus-and-relay-output\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/www.atim.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Catalog EN\",\"item\":\"https:\\\/\\\/www.atim.com\\\/en\\\/catalog\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ACW-MSC-N2Measurement unitfor Enerclip CTs Modbus and relay output\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.atim.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.atim.com\\\/en\\\/\",\"name\":\"ATIM\",\"description\":\"ATIM connects everything\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.atim.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.atim.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.atim.com\\\/en\\\/#organization\",\"name\":\"ATIM Radiocomunication\",\"url\":\"https:\\\/\\\/www.atim.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.atim.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.atim.com\\\/wp-content\\\/uploads\\\/2021\\\/06\\\/logo-atim-130.png\",\"contentUrl\":\"https:\\\/\\\/www.atim.com\\\/wp-content\\\/uploads\\\/2021\\\/06\\\/logo-atim-130.png\",\"width\":131,\"height\":84,\"caption\":\"ATIM Radiocomunication\"},\"image\":{\"@id\":\"https:\\\/\\\/www.atim.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/ATIMRadio\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/atim-radiocommunications\\\/?viewAsMember=true\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCnpb2_Mt4vG2iBkyQX58Zxg\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Enerclip CT measurement unit \u2013 Modbus and relay output","description":"The Enerclip MSC-N2 measurement module enables comprehensive measurement of electrical quantities in a three-phase circuit or three single-phase circuits.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.atim.com\/en\/produits\/enerclip-ct-measurement-unit-modbus-and-relay-output\/","og_locale":"en_US","og_type":"article","og_title":"Enerclip CT measurement unit \u2013 Modbus and relay output","og_description":"The Enerclip MSC-N2 measurement module enables comprehensive measurement of electrical quantities in a three-phase circuit or three single-phase circuits.","og_url":"https:\/\/www.atim.com\/en\/produits\/enerclip-ct-measurement-unit-modbus-and-relay-output\/","og_site_name":"ATIM","article_modified_time":"2026-03-04T15:54:32+00:00","og_image":[{"width":440,"height":440,"url":"https:\/\/www.atim.com\/wp-content\/uploads\/2026\/01\/MSC-N2-1.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@ATIMRadio","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.atim.com\/en\/produits\/enerclip-ct-measurement-unit-modbus-and-relay-output\/","url":"https:\/\/www.atim.com\/en\/produits\/enerclip-ct-measurement-unit-modbus-and-relay-output\/","name":"Enerclip CT measurement unit \u2013 Modbus and relay output","isPartOf":{"@id":"https:\/\/www.atim.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.atim.com\/en\/produits\/enerclip-ct-measurement-unit-modbus-and-relay-output\/#primaryimage"},"image":{"@id":"https:\/\/www.atim.com\/en\/produits\/enerclip-ct-measurement-unit-modbus-and-relay-output\/#primaryimage"},"thumbnailUrl":"https:\/\/www.atim.com\/wp-content\/uploads\/2026\/01\/MSC-N2-1.png","datePublished":"2026-01-21T15:25:46+00:00","dateModified":"2026-03-04T15:54:32+00:00","description":"The Enerclip MSC-N2 measurement module enables comprehensive measurement of electrical quantities in a three-phase circuit or three single-phase circuits.","breadcrumb":{"@id":"https:\/\/www.atim.com\/en\/produits\/enerclip-ct-measurement-unit-modbus-and-relay-output\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.atim.com\/en\/produits\/enerclip-ct-measurement-unit-modbus-and-relay-output\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.atim.com\/en\/produits\/enerclip-ct-measurement-unit-modbus-and-relay-output\/#primaryimage","url":"https:\/\/www.atim.com\/wp-content\/uploads\/2026\/01\/MSC-N2-1.png","contentUrl":"https:\/\/www.atim.com\/wp-content\/uploads\/2026\/01\/MSC-N2-1.png","width":440,"height":440},{"@type":"BreadcrumbList","@id":"https:\/\/www.atim.com\/en\/produits\/enerclip-ct-measurement-unit-modbus-and-relay-output\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.atim.com\/"},{"@type":"ListItem","position":2,"name":"Catalog EN","item":"https:\/\/www.atim.com\/en\/catalog\/"},{"@type":"ListItem","position":3,"name":"ACW-MSC-N2Measurement unitfor Enerclip CTs Modbus and relay output"}]},{"@type":"WebSite","@id":"https:\/\/www.atim.com\/en\/#website","url":"https:\/\/www.atim.com\/en\/","name":"ATIM","description":"ATIM connects everything","publisher":{"@id":"https:\/\/www.atim.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.atim.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.atim.com\/en\/#organization","name":"ATIM Radiocomunication","url":"https:\/\/www.atim.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.atim.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.atim.com\/wp-content\/uploads\/2021\/06\/logo-atim-130.png","contentUrl":"https:\/\/www.atim.com\/wp-content\/uploads\/2021\/06\/logo-atim-130.png","width":131,"height":84,"caption":"ATIM Radiocomunication"},"image":{"@id":"https:\/\/www.atim.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/ATIMRadio","https:\/\/www.linkedin.com\/company\/atim-radiocommunications\/?viewAsMember=true","https:\/\/www.youtube.com\/channel\/UCnpb2_Mt4vG2iBkyQX58Zxg"]}]}},"_links":{"self":[{"href":"https:\/\/www.atim.com\/en\/wp-json\/wp\/v2\/product\/46456","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.atim.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.atim.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.atim.com\/en\/wp-json\/wp\/v2\/comments?post=46456"}],"version-history":[{"count":2,"href":"https:\/\/www.atim.com\/en\/wp-json\/wp\/v2\/product\/46456\/revisions"}],"predecessor-version":[{"id":47071,"href":"https:\/\/www.atim.com\/en\/wp-json\/wp\/v2\/product\/46456\/revisions\/47071"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.atim.com\/en\/wp-json\/wp\/v2\/media\/46463"}],"wp:attachment":[{"href":"https:\/\/www.atim.com\/en\/wp-json\/wp\/v2\/media?parent=46456"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.atim.com\/en\/wp-json\/wp\/v2\/product_brand?post=46456"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.atim.com\/en\/wp-json\/wp\/v2\/product_cat?post=46456"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.atim.com\/en\/wp-json\/wp\/v2\/product_tag?post=46456"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}